12 best ac smoke detectors

AC smoke detectors, also known as hardwired smoke detectors, are a crucial component of fire safety and security systems in homes and commercial buildings. They are designed to detect the presence of smoke or high levels of carbon monoxide (CO) in the air, alerting occupants to potential fire or CO poisoning hazards. These detectors are typically installed directly into the electrical wiring of a building, providing a continuous power source and eliminating the need for frequent battery replacements.

Here are some key features and information about AC smoke detectors:

  1. Smoke Detection: AC smoke detectors use various technologies to detect smoke particles in the air, such as ionization and photoelectric sensors. When smoke is detected, the alarm is triggered, producing a loud audible signal to alert occupants.

  2. Carbon Monoxide Detection: Combination smoke carbon monoxide detectors are designed to detect both smoke and elevated levels of carbon monoxide gas. CO is a colorless, odorless gas that can be produced by faulty heating systems, gas stoves, or vehicle exhaust. CO detectors provide an essential warning of this silent but deadly threat.

  3. Interconnectivity: Many AC smoke detectors can be interconnected with one another, creating a network of detectors throughout a building. When one detector senses smoke or CO, it can trigger all the interconnected detectors to sound their alarms simultaneously, ensuring that everyone in the building is alerted to the danger.

  4. Power Source: AC smoke detectors are wired into a building's electrical system, which means they have a constant power source. This eliminates the need for battery replacement, reducing the risk of the detector becoming non-functional due to dead batteries.

  5. Battery Backup: To ensure that the detector continues to function during power outages, most AC smoke detectors come with a battery backup. This backup power source kicks in if the electricity supply is interrupted, ensuring continuous protection.

  6. Maintenance: While AC smoke detectors require less frequent battery replacement, they still need regular maintenance. It's important to test these detectors regularly, usually by pressing a test button, to confirm that they are functioning correctly. Additionally, they should be cleaned to prevent false alarms caused by dust or debris buildup.

  7. Placement: Proper placement of AC smoke detectors is crucial for effective fire safety. They should be installed on every level of a building, in hallways, near bedrooms, and in common living areas.It's also important to place them near sleeping areas to ensure that occupants are alerted even when asleep.

  8. Compliance: In many regions, building codes and regulations require the installation of AC smoke detectors and combination smoke carbon monoxide detectors in residential and commercial properties. Compliance with these codes is essential for the safety of occupants and may be necessary to obtain building permits or insurance coverage.

In summary, AC smoke detectors and combination smoke carbon monoxide detectors are vital components of fire safety and security systems. They offer continuous protection against the dangers of smoke and carbon monoxide poisoning, with the added benefit of a consistent power source and the ability to interconnect multiple detectors for enhanced safety. Proper installation, maintenance, and compliance with local building codes are essential to ensure their effectiveness.

Below you can find our editor's choice of the best ac smoke detectors on the market
  

First Alert BRK9120b6CP Hardwired Smoke Detector with Backup Battery

FIRST ALERT

Based on 15 reviews Check latest price

Product description

Promote greater household safety with the First Alert 9120B Hardwired Smoke Alarm with Battery Backup. This 120 volt AC smoke detector uses an ionization smoke sensor to reliably detect smoke from hot, fast flaming fires and alerts you with a loud 85 decibel alarm. Designed to be wired directly into your home's electrical system, this hardwired smoke detector features a backup battery that helps keep the alarm functioning even in the event of a power outage. The gasket less mount helps ensure a perfect alignment for easy installation, while tamper resistant locking pins keep the alarm secure. And thanks to the convenient test/silence button, you can easily check whether the alarm is functioning properly and mute false alarms. This smoke alarm can integrate with up to 12 other First Alert or BRK hardwired alarms and features a latching indicator that identifies which unit triggered the alarm.

Introducing the revolutionary BRK 9120 series smoke alarms which have been redesigned from the ground up. They install faster, perform better, and are even smarter than before. All of these improvements help reduce nuisance alarms and save you time and money. BRK Electronics smoke alarms are designed to be easy to install, easy to maintain, and quality-engineered for years of virtually maintenance-free service.

The 9120B AC-powered smoke alarm with battery backup includes these features:

  • Ionization sensor which helps detect fast flaming fires that consume combustible materials rapidly.
  • 120-volt AC inter-connectable (with maximum 18 compatible devices). The alarm can be interconnected with up to 12 other compatible smoke alarms and six compatible devices like bells, horns, repeaters and door closers. If one unit triggers an alarm, all smoke alarms in the series will sound. Power indicators show which unit in the series initiated the alarm.
  • Latching alarm indicator which automatically identifies which unit initiated the alarm.
  • Smart technology to reduce nuisance alarms.
  • 9-volt battery backup for peace of mind during power malfunction.
  • Single test/silence button which both silences a non-threatening alarm or low battery warning and allows you to test the unit's functionality.
  • Perfect mount system including a gasketless base for easy installation and new mounting bracket that keeps the alarm secure over a wide rotation range to allow for perfect alignment.
  • Mounting bracket lock for tamper resistance.
  • Dust cover to keep unit clean during construction.
  • 10-year limited warranty.
All BRK Electronics smoke alarms meet UL 217 standard and are listed with the California State Fire Marshal. They use the new UL mandated repeating 85-decibel alarm horn pattern. 10-year limited warranty. This unit is approved for sale in Oregon after new revisions on law HB2586.--Bree Norlander

What's in the Box

One smoke alarm, one 9-volt battery, and user's manual

From the Manufacturer

The revolutionary BRK 9120 series smoke alarms have been redesigned from the ground up. They install faster, perform better, and are even smarter than before. All of these improvements help reduce nuisance alarms and save time and money. BRK Electronics’ smoke alarms are designed to be easy to install, easy to maintain, and quality-engineered for years of virtually maintenance-free service. The 9120B includes an ionization sensor which helps detect fast flaming fires that consume combustible materials rapidly and is 120-volt AC inter-connectable (with maximum 18 compatible devices), which lets the alarm be interconnected with up to 12 other compatible smoke alarms and six compatible devices like bells, horns, repeaters, and door closers. If one unit triggers an alarm, all smoke alarms in the series will sound. Power indicators show which unit in the series initiated the alarm and a latching alarm indicator automatically identifies which unit initiated the alarm. This is smart technology to reduce nuisance alarms. It also has a 9-volt battery backup for peace of mind during power malfunction, a single test/silence button which both silences a non-threatening alarm or low battery warning and allows you to test the unit's functionality, a perfect mount system, including a gasket less base for easy installation and new mounting bracket that keeps the alarm secure over a wide rotation range to allow for perfect alignment, and a mounting bracket lock for tamper resistance. A dust cover keeps the unit clean during construction. It comes with a 10-year limited warranty.

  • Keep your family safe with this hardwired smoke alarm the battery backup means constant monitoring, even if there's a power failure
  • Equipped with an ionization sensor, this smoke alarm reliably detects smoke from fast flaming fires and alerts you with an 85 decibel alarm
  • To ensure complete protection make sure to place one on each level of your home and in each bedroom
  • Can connect to other compatible BRK or first alert smoke detectors, to ensure all alarms will sound when smoke is detected
  • Simple to use, with a single test/silence button, and side load battery compartment tamper resistant locking brackets and universal mounting brackets make installation easy
  • Rigorously tested to meet UL standards120 volt AC power with 9V battery backup to keep alarm functioning during power outage
  • First Alert has been the most trusted brand in home safety since launching the first residential smoke alarm in 1958 (Based on a First Alert Brand Trust Survey in February 2018)
  • Faster turnarounds on job sites with the easy-to-install, most-trusted alarms in home safety

User questions & answers

Question: My entire home is equipped with BRK smoke detector (4120 B) and Carbon Monox Det (CO50120B). They need replacing. Will new BRK fit extant casings
Answer: Yes all the wired Nest Protect needs is the 120V hot (black) and neutral (white) wires in the electrical box connected to the plug-in pigtail that comes with the Protect. If your house has multiple detectors now you will usually also find a red wire in the electrical box that interconnects your old detectors so that if one goes off they all sound. That wire is no longer needed with the Protect so you just cap it with a wire nut.
Question: can these be connected together so if one is set off they all go off
Answer: Yes, but only if you are connected to the internet and then only for the last ten days, and only if the level rises above the heads up level (which is 70ppm and rising for around an hour or a shorter period if over 150ppm). To counter what someone else's answer was - Carbon monoxide does NOT sink. It is in fact lighter than air (CO has an atomic weight of 28 versus Nitrogen (N2) which is also 28 - but marginally heavier (by 0.003 amu due to heavier isotopes), Oxygen (O2) which is 32 and Argon which is 40. However the weight is similar enough in the air in your house that it tends to distribute as a fluid and is measurable anywhere in a room; it really depends upon how air moves through the space. The levels tend to fluctuate rapidly as CO distributes and any outside air mixes in and additional CO is added. Overall, there is no perfect way to measure the CO levels with one device in one place, but this is as good as most people need.
Question: How does the Alarm Latch feature "easily identify initiating alarm"? This is major problem with false alarms on my existing Kidde/Firex dual alarms
Answer: I just checked this for you. I unplugged my wifi router and started a test. All detectors alarmed as expected. So, yes, the system works even without active wifi.
Question: Can a BRK Model 92120B smoke detector directly plug in and replace an old BRK Model 4120B smoke detector (without an adapter
Answer: I think very few here understand the question. National code requires interconnected smoke detectors as of 2004, there is an extra wire in the circuit and all smoke detectors are on that wire for 'signal'. When one alarms they should ALL alarm. If I am reading the answers correctly, NEST does not comply with the signal wire. However, it looks like it does set up its own wireless network to act like they are all interconnected. To be honest, after paying for the extra wire behind the wall, why would I want to by 6-8 nests at $100 each when the originals are 20-30 each? This way there is one smart point to notify if any detector is going off. Nests way 6-9 smoke detectors, 6-8 login, 6-8 ip address. Ugh, what a nightmare!

Product features

Smoke Alarms

Place at least 10 feet from kitchen/stove, and on the ceiling or high on a wall, no more than 10 inches from top.

Carbon Monoxide Alarms

Carbon monoxide alarms can be placed anywhere, not just the ceiling or high on a wall. They should be replaced every 5 to 7 years.

Fire Extinguishers

Keep in the kitchen and garage, but make sure to have the right grade for the type of fire that might occur.

Escape Ladders

Have at least one if your home has more than one story. Each room needs 2 escape routes; in most bedrooms it's the window, so have a ladder nearby.

Kidde i12060 AC DC Hardwired Smoke Alarm Ionization Battery Backup

Kidde

Based on 366 reviews Check latest price

Product description

The Kidde i12060 is an AC/DC powered, ionization smoke alarm that operates on a 120V power source with 9V battery backup. This alarm uses ionization sensing technology.

  • Front battery pull tab allows battery activation without removing alarm from mounting bracket. Large mounting base makes mounting easier, protects surface paint from dirt and covers imperfections. Pre-stripped wiring harness with easyoff cap does not require stripper tool.
  • Interconnectable with up to 24 devices (of which 18 can be initiating including smoke, CO and heat alarms.
  • Battery backup provides protection in case of power failure
  • UL Listed, 10 Year Warranty
  • Front battery door makes replacing the battery easy for anyone.

User questions & answers

Question: what's the difference between generation 1 and generation
Answer: Not sure. We have a 5600 and it fits perfectly
Question: I need to replace a kiddie 1276. Is this compatible with connection and mounting plate
Answer: I don't know if it fits the 5400. I have a pool frog and it fit perfectly. Sorry wish I knew what the 5400 was.
Question: Are all Kidde i12060 alarms interchangable, or do I need to replace with my original model number (408-21006376) as well
Answer: This tool contains a 9/16 inch and 7/8 inch socket, which should cover most of the more popular filter tanks.
Question: What is the mfr date of this unit
Answer: Not sure on gauge, but used it to repair large triangle rip in pool liner (12” by 14”) formed over winter where an old small patch gave way and with extra put bigger patches over other small ones, it has stood up to my dog scratching over new patch and elements so far, so as a pool liner fix, the gauge is sufficent

Product features

Kidde AC Hardwired Smoke Alarm

  • Provides a Hush feature to quickly silence nuisance alarms
  • Tamper resist locking feature deters alarm theft
  • Alarm memory flashes red LED indicating which unit was the initiating alarm in interconnected system
  • Battery backup provides protection in case of power failure
  • Interconnectable with up to 24 devices (of which 18 can be initiating) including smoke, CO and heat alarms.

Fewer Callbacks

  • Front battery door makes replacing the battery easy for anyone.
  • One button design for easy operation and less confusion. Operates Hush and alarm test.
  • Battery run down protection will shut down alarm memory when AC power is not present, reducing low battery chirp.
  • Dust cover protects sensor from contaminates during construction reducing nuisance alarms.

First Alert BRK SC9120LBL Hardwired Smoke and Carbon Monoxide (CO) Detector with 10 Year Sealed Battery Backup

FIRST ALERT

Based on 468 reviews Check latest price

Product description

The brk SC9120LBL alarm features a dual ionization smoke sensing chamber and an electrochemical carbon monoxide sensor, an 85Db horn and a "silence" feature. This alarm features a 10 year battery backup. The battery drawer is shipped pre locked so battery will not be discarded prematurely. Under normal conditions you should not have to replace the battery for the life of the alarm. "Intelligent sensing technology" system is designed to reduce nuisance alarms. "Latching alarm indication" remembers which unit initiated an alarm. When interconnected in a series, the unit that triggered the alarm rapidly flashes its red LED indicator. After the alarm condition subsides, the initiating unit will store in memory or "latch" the information and begin to flash the LED indicator 2 seconds on, 2 seconds off. The "perfect mount" system features a gasketless base and a mounting bracket that keeps the alarm secure over a wide rotation range to allow for true alignment. Other contractor preferred features include a dust cover to keep alarm clean during construction, keyhole slots in the mounting bracket eliminate the need to remove the electrical box screws for installation. Two locking features are provided to prevent battery theft and/or theft of the unit. Connection to AC power is made with a "quick connect" Wiring harness. Installation is quick, easy and cost effective.

  • Keep your family safer with this hardwired smoke and carbon monoxide alarm; The 10 year battery backup means constant monitoring for the life of the alarm even if there's a power failure
  • Features an electrochemical Carbon Monoxide sensing technology as well as intelligent smoke sensing technology to reduce nuisance alarms; Keyhole slots in the mounting bracket eliminate the need to remove the electrical box screws for installation
  • Indicator lights on the face of the unit display the presence of smoke or carbon monoxide, while an 85 decibel siren provides a clear, loud warning upon detection
  • Simple to use, with a single test/silence button; Included 10 year lithium battery features a locked drawer to prevent tampering
  • 10-year limited warranty; Equipped with end-of-life signal chirp, so you know when it’s time to replace the unit for safety
  • Rigorously tested to meet UL standards, Emits T3 pattern
  • Faster turnarounds on job sites with the easy-to-install, most-trusted alarms in home safety
  • First Alert has been the most trusted brand in home safety since launching the first residential smoke alarm in 1958 (Based on a First Alert Brand Trust Survey in February 2018)

User questions & answers

Question: can it run independently off a battery
Answer: No they do not and I have one pretty much over the stove. Most detectors don't go off around the kitchen area unless it detects a large amount of smoke.
Question: Why can't i get 12 pack of 10 year sealed battery backup, brk sc9120lbl ? i can buy only 1 at a time
Answer: No, they don’t have WiFi and there’s no app. They are just good reliable smoke detectors that are powered by a built in lithium battery that lasts 10 years. Install and test once a year.
Question: Can anyone explain why these arrive in bubble wrap in a cardboard box instead of in the self contained blister pack, like they are in retail stores
Answer: Yes
Question: What if my device does not show any light? But when click Test it does sound
Answer: This item is manufactured in China.

Kidde i12040 120v Ac/dc Smoke Alarm w/ Battery Back up Lot of 6 by KIDDE

Kidde

Based on 1 reviews Check latest price

Product description

The Kidde i12040 contractor 6 pack is sold as one master pack that contains 6 individual units. These alarms are 120-Volt hardwired ionization smoke alarm with 9-Volt battery backup and Hush feature. Smoke alarms have the ability to function as single units or in an interconnected system.



Test button, tests unit's electronic circuitry, horn, and battery function

9-Volt battery back up (21025830)

Quick connector - makes installation fast and easy

Tamper resist locking pin - helps deter alarm tampering and theft

Hush feature - temporarily silences nuisance alarms



Voltage (volts): 120

Connector/Contact Type: 3-Wire

Alarm/Detector Features: Battery Back-Up,Hush Feature,Interconnected,Value Pack

Pack Size: 6

Alarm Type: Smoke

Commercial / Residential: Commercial / Residential

Power Source: Hardwired

Included: Batteries

Alarm Sensor Type: Ionization

Certifications and Listings: 1-UL Listed





Product Width (in.): 6.6

Product Height (in.): 6.5

Product Depth (in.): 10.7

Ship Width: 8

Ship Height: 10

Ship Length: 12

  • Hush feature temporarily silences nuisance alarms
  • One touch test button tests unit's electronic circuitry
  • Battery backup 9V battery included
  • Tamper resist locking pin helps deter alarm tampering and theft
  • UL Approved

User questions & answers

Question: is it photoelectrict? Can it be connected to a fire alarm system
Answer: Your warranty starts at the date of purchase. Keep your receipt. Your 5 year shelf life starts the day you power it up. The expiration date is hard coded into the software and only starts the day you plug it in..... This is from BRK WEBSITE
Question: Have u noticed high electric bill
Answer: It doesnt matter. If you have a device alarming, you, family and pets need to remove yourself from the house and possibly call fire department. Both sources will kill you.
Question: is this detector one that is disposed off when battery is down
Answer: According to the National Fire Protection Association: Choose smoke alarms that have the label of a recognized testing laboratory.Install smoke alarms inside each bedroom, outside each sleeping area and on every level of the home, including the basement.On levels without bedrooms, install alarms in the living room (or den or family room) or near the stairway to the upper level, or in both locations.Smoke alarms installed in the basement should be installed on the ceiling at the bottom of the stairs leading to the next level.Smoke alarms should be installed at least 10 feet (3 meters) from a cooking appliance to minimize false alarms when cooking.Mount smoke alarms high on walls or ceilings (remember, smoke rises). Wall-mounted alarms should be installed not more than 12 inches away from the ceiling (to the top of the alarm). If you have ceilings that are pitched, install the alarm within 3 feet of the peak but not within the apex of the peak (four inches down from the peak).
Question: I am looking at replacing my kidde 1275 smoke alarms, which should I replace with as mine were made
Answer: The "radioactive part" is how it works. Don't like it? Don't buy it. Simple. As for false alarms, this unit with its "radioactive part" is actually much more likely to give false alarms that condition people to ignore them. It is also much less sensitive to the smoldering, smoke-producing fires that are more common in homes. That's why ionization detectors are no longer recommended in residential settings. Experts now recommend only photoelectric devices in homes, so if you have these, you should replace all of them with the SC7010B.

Kidde 21026063 AC Hardwired Smoke Detector Alarm with 9V Back up and Front Load Battery Door

Kidde

Based on 1 reviews Check latest price

Product description

The Kidde i4618 is an AC/DC powered ionization smoke alarm that operates on a 120V power source with 9V battery backup This alarm uses ionization sensing technology Ionization sensing alarms may detect invisible fire particles (associated with flaming fires) sooner than photoelectric alarms Photoelectric sensing alarms may detect visible particles (associated with smoldering fires) sooner than ionization alarms.

SMOKE ALARM FEATURES

• Model ADC features a False Alarm Control which, when activated, quiets unwanted alarms for up to 15 minutes.

• This smoke alarm is powered by 120V AC and a 9-volt battery back-up source. AC/DC smoke alarms offer added protection in the event of a power failure or a drained battery.

• Unique power connector prevents interconnection with incompatible smoke alarms or security systems.

• This smoke alarm may be interconnected with as many as 11 other Firex model FADC, AD and ADC smoke alarms, or as many as 6 Firex model ADH heat alarms for a total of not more than 18 interconnected devices.

• Optional tamper-resist feature can serve as a safeguard against tampering. • Unique “battery missing” lockout. The smoke alarm will not attach to the mounting bracket if a battery is not in the battery pocket.

• Improperly connected or weak battery signal. The smoke alarm will sound a short beep about once a minute if the battery is weak or improperly connected.

• Separate green and red LEDs indicate that the smoke alarm is receiving AC power, working under normal operation, in alarm, or under false alarm control.

• Loud alarm horn—85 decibels at 10 feet—sounds to alert you to an emergency.

• This alarm incorporates the internationally recognized horn signal for evacuation. During alarm mode, the horn produces three short beeps followed by a 2 second pause and then repeats. This pattern is somewhat different than the previous alarm sound, which continually beeped.

• Test button checks smoke alarm operation. Model ADC also features a False Alarm Control which, when activated, quiets unwanted alarms for up to 15 minutes.

  • Easy Installation - Front battery pull tab allows battery activation without removing alarm from mounting bracket. Large mounting base makes mounting easier, protects surface paint from dirt and covers imperfections. Pre-stripped wiring harness with easy off cap does not require stripper tool. Tinned strands increase conductivity and wire nut grip.
  • Fewer callbacks - Large centrally located Test/Hush alarm control button. Dust cover protects sensor from contaminates during construction reducing nuisance alarms.
  • User-friendly features - Easy access front loading battery door. Battery backup provides protection in case of power failure. Interconnectable with up to 24 devices (of which 18 can be initiating) including smoke, CO and heat alarms. See user’s guide for complete instructions.
  • Alarm memory flashes red LED indicating which unit was the initiating alarm in interconnected system. Temperature range: 40 degree Fahrenheit to 100 degree Fahrenheit
  • Tamper resist locking feature deters alarm theft. Audio Alarm-85dB at 10feet

User questions & answers

Question: Is this a replacement for FireX FADC
Answer: I do not know the answer, however FYI, I replaced all of my smoke detectors with these because of the 10 yr warranty. I have 12 foot ceilings & had to have a friend install them. I used 9. Within 24 hrs, 3 of them were chirpoing & another 3 a few hours later. I ended up replacing them all. Check the expiration dates before using. I won't purchase them again.
Question: Does the package include the KA-F adapter
Answer: I did not receive all of the batteries I only receive half of the order.
Question: Is i4618 interchangeable with Firex 120-538B? Can I attach to the same base
Answer: Yes, The lithium is a much longer lasting battery.
Question: Is this a replacement for Firex 120-538B
Answer: You can buy First Alert brand that you can program them so if one goes off all of them go off same time . But it’s not 10 year battery .

Product features

Easy Access

The front-loading battery door ensures that you never have to remove this smoke alarm from its mounting bracket if the backup battery needs to be replaced, allowing you to address low battery alerts without hassle or worry. Additionally, the front battery pull tab allows battery activation while the unit is mounted.

Safe and Confident

Sleep soundly at night, knowing your family is safe and prepared for any emergency, with the Hardwired Smoke Detector from Kidde. This smoke alarm uses an advanced ionization sensor, which can detect invisible fire particles associated with flaming fires, and includes a battery backup to ensure your peace of mind in any situation. It can be interconnected to compatible alarms and will provide the highest quality of safety.

One Button Design

The single button operates Test/Reset and the Hush feature. To reduce nuisance alarms from smoky or overcooked dinners, this smoke detector features our Hush Mode. The front button will desensitize the alarm for up to 8 minutes, silencing the alert if the smoke is not too dense. This can be used repeatedly until the condition is cleared, and also silences low battery alerts.

Kidde AC Hardwired Interconnect Smoke Alarm with Hush i12040 4 Pack

Kidde

Based on 431 reviews Check latest price

Product description

The Kidde i12040 is an AC/DC powered, ionization smoke alarm operating on a 120V power source with 9V battery backup. The Kiddie i2040 is an interconnected ionization smoke alarm that provides a dependable warning against potential fires through its ability to link up with other Kidde-compatible alarms. This means you'll be able to hear a single alarm no matter where you are in your home. The 120V, AC-powered alarm provides the earliest warning of smoke or fire threats, even during power outages. It also comes with a hush feature to temporarily silence nuisance alarms and a one-touch button to test the unit’s electronic circuitry. The Kidde i12040 is convenient and reasonably priced. It provides a low profile, sleek design and comes with added protection and assurance with its included 9V battery backup. With temperature and relative humidity durability and the latest ionization sensing technology, the Kidde i12040 with alarm memory is the perfect alarm for any home. The Kidde i12040 has a horn alarm at an adequate 85 dB, is UL listed .

  • Hush feature temporarily silences nuisance alarms
  • One touch test button tests unit's electronic circuitry
  • Battery backup 9V battery included
  • Tamper resist locking pin helps deter alarm tampering and theft
  • UL Approved

User questions & answers

Question: Do these smoke alarms carry a 10 year warranty
Answer: Vinyl adhesive
Question: Do I need to purchase the adapters to plug into my existing bases
Answer: Find a pool maker and order the size you need.
Question: Why does the picture show 6 when the description says 4 pack
Answer: Not the best idea. Too many potential leak points when joining the pieces together.
Question: Kidde compatibility list states firex 120-1072 = this model. What other alterations need to be made to install
Answer: We used it and it held for about 8 mi the with no trouble. It was just above the water line so in the splash zone!

Kidde Nighthawk Plug-In AC/DC Carbon Monoxide Alarm Detector with Digital Display KN-COPP-3

Kidde

Based on 15 reviews Check latest price

Product description

Plug-In carbon monoxide alarm with battery backup.

Protect your family from the dangers of carbon monoxide (CO) exposure with the Kidde KN-COPP-3 Nighthawk Plug-In Carbon Monoxide Alarm with Battery Backup and Digital Display. The Nighthawk is an easy-to-install unit that provides reliable protection against the dangers of CO. It features a digital display that shows CO levels in parts per million allowing you to see if, how, and when levels change.

callout top
  • Plug-in unit with battery backup and digital display that shows CO level
  • Level button displays the peak CO level recorded by the alarm since it was last reset
  • Loud alarm pattern sounds when unit detects elevated CO levels
  • Direct-plug, 6-foot power cord, and table top mounting options.

  • Five-year limited warranty
callout top
Kidde KN-COPP-3 Nighthawk Carbon Monoxide Alarm


This discreet alarm is designed to fit into any standard A/C outlet in your house.

View larger.


Kidde KN-COPP-3 Nighthawk Carbon Monoxide Alarm


The easy-read digital display updates every 15 seconds to indicate any abrupt changes or alarming trends in CO levels. View larger.
Advanced Technology in an Easy-to-Install, Plug-In Design

Designed for home use, the Kidde KN-COPP-3 Nighthawk is a UL-listed, A/C-powered, plug-in CO alarm that utilizes sophisticated electronic components and sensor technology to protect you and your family from the dangers of CO. It plugs directly into a standard A/C outlet and includes a 9-volt battery backup that provides continuous monitoring of CO levels--even during power outages.

About Carbon Monoxide: The Silent Killer

The leading cause of accidental poisoning deaths in North America, carbon monoxide (CO) is often referred to as the silent killer because it's odorless, tasteless, and invisible. Carbon monoxide poisoning can come about via a number of sources, including everyday items and appliances in your home or office. And because symptoms of CO poisoning mimic the flu or other common illnesses it can often go undiagnosed.

Audible Alarm Pattern Alerts you to Elevated CO Levels

When placed on every level of your home, alarms like the KN-COPP-3 Nighthawk can help protect everyone in the house from CO exposure by giving you an unmistakable signal when levels have reached an unhealthy point. If unhealthy levels are detected, the alarm will emit four quick audible beats every five seconds until either levels decrease or the reset button is pressed.

Easy-to-Read Digital Display Shows CO Levels

The KN-COPP-3 Nighthawk is unique among traditional CO alarms because of its digital display. This display clearly shows levels of CO that the unit has detected and stored-- from 30 to 999 ppm--and it updates every 15 seconds to indicate any abrupt changes or alarming trends. The display also shows the peak CO level recorded by the alarm since it was last reset or unplugged.

LED Shows Sensor Status

With the KN-COPP-3 Nighthawk, you never have to wonder if the sensor is functioning properly. A blinking dot in the lower right-hand corner of the display denotes normal operation, so you can trust that it's working. In addition, you can test alarm function by pressing the test/reset button at any time to verify that the horn and electric circuitry are operating properly.

Convenient Mounting Options

The KN-COPP-3 Nighthawk has a low-profile design that makes it suitable for any room in your home. The detector can be plugged into any standard A/C outlet; it's plug can be snapped into the back of the unit and can be rotated so the alarm remains vertical, independent of whether the electrical socket is mounted vertically or horizontally. In addition, the alarm comes with a 6-foot extension cord, so the unit can be plugged into the wall outlet and then placed on a table or shelf. For the most thorough protection, place an alarm on every level of your home.

The UL-listed Kidde KN-COPP-3 Nighthawk has a seven-year life and is backed by a five-year limited warranty.

About Kidde: A UTC Fire and Security Brand

Renowned for global leadership in fire detection and suppression, Kidde provides solutions ranging from portable fire extinguishers to advanced industrial controls such as flame detection and explosion suppression systems. Kidde is a UTC Fire and Security brand, with a history that's rich with innovations, from the patent of the Chubb Detector Lock in 1818 to the development of the world's first wireless networked smoke detectors in 2004.

What's in the Box

Kidde KN-COPP-3 Nighthawk CO Alarm, 9-volt battery, mounting hardware, and installation guide.



Kidde KN-COPP-3 Nighthawk Carbon Monoxide Alarm


Keep your family safe by placing alarms and extinguishers in each area of the house, and by having a fire escape plan. Click here for a detailed image.


From the Manufacturer

The leading cause of accidental poisoning deaths in North America, Carbon Monoxide is odorless, tasteless and invisible, it's a silent killer. Kidde CO alarms include the most accurate sensing technology available, the patented Nighthawk electrochemical sensor. This alarm can be mounted three ways: plug directly into AC receptacle, mount on tabletop using 8 foot power cord, or wall-mount. The digital readout continuously displays carbon monoxide levels from 30-999 parts per million. This unit has a loud, 85-decibel alarm that sounds when CO reaches dangerous levels. One of the features of this product is peak level memory, which means this unit will recall highest level of CO present since previous reset. Install at least one CO alarm on every floor and in sleeping areas. Make sure CO alarms are at least 15 feet away from cooking or heating appliances to prevent false alarms. Replace CO alarms every 5 to 7 years to benefit from the latest technology upgrades.

  • Peak level button – Displays the peak CO level recorded by the alarm since it was last reset or unplugged
  • Test button functions – Tests the unit for proper operation and resets the carbon monoxide alarm
  • LED operation – Blinking dot in lower right corner of display denotes normal operation
  • Ten years after the initial power up, this alarm will “beep” two times every 30 seconds to indicate that it is time to replace the alarm.
  • Note: This CO alarm is not battery operated. However, these alarms are equipped with 9 volt battery backup – the 9 volt battery is to supply short term back-up during a power outage.
  • Power source: 120VAC. Temperature range-40˚F (4.4˚C) to 100˚F (37.8˚C). Humidity range-5%-95% relative humidity (RH)

Product features

Easy to Read Display

This plug-in CO alarm is designed with a clear, visible readout that will accurately record the levels of carbon monoxide present so that you can quickly know if an area of your home is at risk. It measures CO levels between 30 and 999PPM, and the display will also indicate if the battery needs to be replaced.

Unbeatable Protection

Always protect your family and home by making sure you are prepared for any emergency or hazard with the Kidde plug-in carbon monoxide detector. This CO meter uses an electrochemical sensor and features a clear digital display screen to monitor and record any CO levels in any room of your house. This sensitive and clear detector will leave you confident that you are protected against carbon monoxide.

Peak Level Memory Feature

Displays the peak CO level recorded by the alarm since it was last reset or unplugged

Kidde - 21026045 AC Hardwired Wireless Interconnect Smoke Detector Alarm | Model RF-SM-ACDC

Kidde

Based on 167 reviews Check latest price

Product description

Kidde offers two wireless product options: a Battery Powered Smoke Alarm, and an AC Powered Smoke Alarm. These products enable you to customize your system based on your specific needs. Read below to see which Kidde wireless smoke alarms are best for your home. Kidde Wireless Smoke Alarms enable you to extend the coverage and protection of interconnected smoke alarms —without any need for additional wiring! This alarm uses ionization sensing technology. Ionization sensing alarms may detect invisible fire particles (associated with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible particles (associated with smoldering fires) sooner than ionization alarms. Kidde strongly recommends that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fire that can occur within the home. The Kidde Wireless AC Powered Smoke Alarm makes it easy to expand the coverage of a current interconnected system. Simply replace one interconnected smoke alarm with the Kidde Wireless AC powered alarm. Kidde Wireless Battery Powered Smoke Alarms can be installed in additional rooms that need extra protection. This AC powered alarm bridges a home’s current interconnected system to the newly installed alarms, so that when one alarm is triggered, all alarms will sound. Experts recommend interconnected alarms, because when one sounds, they all sound, providing an early warning against fire by dramatically increasing your ability to hear an alarm anywhere in your home, regardless of where the fire starts. Newer homes are required by code to have interconnected alarms. Wireless technology now enables any home to have an interconnected system.

  • Makes it easy to expand the coverage of a current interconnected system
  • When one alarm sounds, they all do: wireless technology uses radio frequency to both transmit and receive messages about a hazard in the home
  • AC power with battery backup enables homeowners to expand a current interconnected system.Temperature Range:40F (4.4C) to 100F (37.8C)
  • Two universal adapters are included, allowing it to be used with most existing interconnected systems
  • Smart touch button quickly and temporarily silences nuisance alarms. Power Source - 120VAC; 9V battery backup. Audio Alarm- 85dB at 10ft
  • Wireless interconnect is compatible only with other RF-SM-DC models; or with other RF-SM-ACDC by leaving the red wire disconnected

User questions & answers

Question: Can hardwired work to other hardwired
Answer: Yes! I just replaced mine and the 12040 is a plug-n-play replacement for the 1275. No changing of electrical or base (if you don't want to.) I changed a couple of bases because of discoloring, however, it didn't need to be done. Very happy with the product.
Question: Can this smoke detector be used in an unheated garage? We live in an area where it gets below zero at times in the winter
Answer: The Kidde i12040 units are "perfect" replacement units (same interface and can swap out) for our previous Kidde 1275 units. I didn't have to change the short electric connector or the ceiling mounting plate. I installed them in early November 2014, and so far all are functioning fine. I replaced four of our six units. When I tested the new detectors, all units -- both the older ones and the new ones -- triggered and alarmed properly. I did replace the mounting units because the old ones were fading... if yours are still in good condition, you don't have to change them. The new plates are identical, and can be installed in the exact same position as the existing plates, and using the existing screws without re-positioning them.Hope this helps. Feel free to contact me for any additional questions on this./Larry -- [email protected]
Question: How to make the order since i need the installation of three kidde ac hardwired wireless interconnect smoke alarms in my house on different floors
Answer: Hello. We here at Kidde are not sure what they are talking about with Generation 1 and Generation 2. We did upgrade our model about 10 years ago from the I12060 to the I12060A. A low battery hush feature was added where if you pushed the test button while it was chirping for low battery, it would stop chirping for low battery for 10 hours. Also there were minor changes in how the red LED indicators indicated alarm memory mode and HUSH mode to save on the battery. The boxes for the alarms and descriptions online will still say I12060 but you are nearly guaranteed to get the I12060A in the box. If you have any issues, please call us at 1-800-880-6788 and let us see if we can figure out what you get and how we can help.
Question: Is this the same as kidde model rf-sm-acdc? the kidde web site doesn't list any model rf-sm-ac
Answer: Hello. Yes, this alarm has the exact same plug and the exact same mounting bracket as the 1276.

Product features

Hardwire 120Volt Wireless Inter-Connectable Smoke Alarm with Battery Backup

The Kidde Wireless AC Powered Smoke Alarm makes it easy to expand the coverage of a current interconnected system. Simply replace one interconnected smoke alarm with the Kidde Wireless AC powered alarm. Kidde Wireless Battery Powered Smoke Alarms can be installed in additional rooms that need extra protection. This AC powered alarm bridges a homes current interconnected system to the newly installed alarms, so that when one alarm is triggered, all alarms will sound.

Smoke detector requires hardwired installation
All interconnected alarms will sound when one alarm goes off
Alarm features wire-free interconnectivity via radio frequency

Kidde KN-COPE-IC AC Photoelectric Smoke and Carbon Monoxide Detector Alarm Hardwired With Battery Backup

Kidde

Based on 272 reviews Check latest price

Product description

The Kidde Front-Loading Smoke and Carbon Monoxide alarm (part 21007624) offers protection from two hazards – fire and CO – in one unit. This AC-wire with battery backup alarm emits a beeping tone followed by a voice warning that clearly announces the danger by saying, “Fire, Fire” or “Warning, Carbon Monoxide. ” The uniquely designed front loading battery compartment makes battery replacement quick and easy, and ensures proper installation. Manufactured with photoelectric sensors for detecting smoke and fire, this alarm also includes the world’s most accurate CO sensing technology based on claims by major manufacturers. Architectural and Engineering Specifications - The combination smoke and carbon monoxide alarm shall be Kidde Unit Number KN-COPE-I (part number 900-0213) or approved equal. It shall be powered by 120VAC, 60Hz source with a 9V battery backup. The temperature operating range shall be between 40°F and 100°F (4°C and 38°C) and the humidity operating range shall be 5% - 85% relative humidity. The unit shall incorporate a photoelectric smoke sensor with nominal sensitivity of 2.05%/ft. The CO sensor shall be of a fuel cell design and shall meet the sensitivity requirements of Underwriters Laboratories UL2034 Single and Multiple Station Carbon Monoxide Detectors. The unit shall qualify for UL-approved wording on the package: “World’s Most Accurate Carbon Monoxide Alarm”. The combination alarm can be installed on the surface of any wall or ceiling following the UL/NFPA/Manufacturer’s recommended placement guidelines. The alarm can be installed on any standard single gang electrical box, up to a 4”octagon junction box. The electrical connection (to the alarm) shall be made with a plug-in connector. The unit shall provide optional tamper resistance that deters removal of the unit from the wall or ceiling. No additional pieces shall be required to activate this feature. A maximum of 24 Kidde devices can be interconnected in a multiple station arrangement. The interconnect system must not exceed the NFPA (National Fire Protection Association) limit of 18 initiating devices, of which 12 can be smoke alarms. With 18 initiating devices (smoke, heat, CO, etc.), interconnected, it is still possible to interconnect 6 strobe lights and or relay modules. The alarm shall include a test button that will electronically simulate the presence of smoke and CO and cause the unit to go into both modes of alarm. This sequence tests the unit’s electronics to ensure proper operation. The CO sensor will not alarm to levels of CO below 30 ppm and will alarm in the following time range when exposed to the corresponding levels of CO. 70 ppm CO Concentration 60 – 240 minutes 150 ppm CO Concentration 10 – 50 minutes 400 ppm CO Concentration 4 – 15 minutes The combination alarm shall have two methods of warning for danger: a piezoelectric horn that is rated at 85 decibels at 10 feet and a voice warning that identifies the danger. For a CO incident, the horn will sound in the repetitive manner – four fast beeps, a short pause, four fast beeps, a short pause. In between, the unit will announce “Warning Carbon Monoxide ” In a Smoke incident, the horn will sound in the repetitive manner – three beeps, a pause, three beeps, a pause. In between, the unit will announce “Fire! Fire! ” The unit shall incorporate 2 LED’s. A green LED will be steady on when AC power is present, flash every 30 seconds when in the battery only mode, every 16 seconds to indicate alarm memory, and every 2 seconds to indicate the Hush“ mode is active. A red LED will flash in unison with the sounder pattern. The unit shall include the Smart Hush feature that silences the unit for approximately 8 minutes if a nuisance alarm condition occurs. The Green LED on the alarm will flash every 2 seconds while in Smart Hush and will automatically reset itself. It also provides voice annunciation of “Hush Activated” when Smart Hush is activated and “Hush Cancelled” when the Hush cycle ends. The unit shall also indicate a low battery warning utilizing each of the following methods: a brief alarm chirp, the voice announcement of “Low Battery! ” The unit shall at a minimum meet the requirements of UL 2034, UL217, NFPA72, (chapter 11 2002 edition) The State of California Fire Marshall, NFPA101 (One and two family dwellings) Federal Housing Authority (FHA), Housing and Urban Development (HUD). It shall also include a 10-year manufacturer’s limited. Claim approved by UL, based on manufacturer’s reported testing.

  • Provides protection from fire and carbon monoxide in one unit with Photoelectric sensor.
  • Fire Warning: The red LED will flash and be accompanied by three long alarm beeps followed by a verbal warning message “FIRE FIRE ”. The alarm will repeat pattern until unit is reset or smoke is eliminated.
  • Carbon Monoxide Warning: Four short alarm beeps followed by a verbal warning “Warning carbon monoxide ” This continues until the unit is reset or the CO is eliminated.
  • Low Battery Warning: One chirp followed by warning “LOW BATTERY”. The red LED light will flash. This pattern will continue every minute for the first hour. After the first hour the red LED light will flash once every minute accompanied by the chirp sound. The “LOW BATTERY” warning will only sound once every fifteen minutes. Voice Hush Indication: “HUSH ACTIVATED” and “HUSH CANCELLED” voice announcement
  • Alarm Memory: The green LED will blink once every 16 seconds to alert a user when the unit has alarmed for smoke or has detected a concentration of CO. If the alarm has detected a CO level of 100ppm or greater, when the Test/Reset button is pressed the unit will announce “CO PREVIOUSLY DETECTED”. If the alarm has detected abnormal levels of smoke since its last test, it will produce three rapid beeps.

User questions & answers

Question: When these are interconnected with other units, can hushing one of them hush all of them? Some of mine are in places that are hard to get to
Answer: This RF-SM-ACDC alarm will interconnect wirelessly to other RF-SM-ACDC alarms and will interconnect through a 3 wired circuit to other Kidde hardwired alarms.
Question: does it come with the hardwire connector
Answer: The unit is not designed for temperatures below 60F or above 100F.
Question: Do you have to hardwire it in? Can it run on just the battery
Answer: I have one hardwired and two battery powered. I just followed the instructions and it all worked out. easy.
Question: How do you tell if it is working properly. Is it supposed to have a constant light
Answer: The rf-sm-ac is the hard wired model with battery backup, the rf-sm-dc is the battery powered unit which is not hard wired.

Product features

Always Alert

In order to monitor your home even if you are away, this detector includes an Alarm Memory feature. If the green LED is blinking once every 16 seconds, the unit has detected CO levels of 100PPM or higher, or detected smoke and then ceased its alarm. Pressing the Test/Reset will reset the memory and inform you of the hazard detected.

Easy to Install

Ensure the safety of your family and home with the combination smoke and carbon monoxide alarm from Kidde. This is a hardwired alarm that can be used in an interconnected system, and it features a battery backup, in addition to voice alerts. Using an advanced photoelectric sensor, capable of detecting visible fire particles associated with smoldering fires, and an electrochemical sensor for CO detection, you can rest easy and feel protected.

Easy Access

If the low battery warning sounds, there is a convenient front-loading battery door so that you don’t have to remove the alarm from its mounting bracket to replace the alarm. Additionally, to ensure that there is always a properly functioning battery, the battery compartment will not close if the battery is not installed correctly.

Kidde AC Hardwired Interconnect Smoke Alarm with Safety Light I12080

Kidde

Based on 324 reviews Check latest price

Product description

This alarm uses ionization sensing technology. Ionization sensing alarms may detect invisible fire particles (associated with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible particles (associated with smoldering fires) sooner than ionization alarms. Kidde strongly recommends that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fire that can occur within the home. The Kidde i12080A is an AC/DC powered, ionization smoke alarm that operates on a 120V power source with 9V battery backup. The i12080A includes a quick connect wiring harness for easy installation. The safety light illuminates to guide you to safety. This smoke alarm is available in a 6-piece cut case with tray for easy display. This unit is a UL Listed product with a 10-year limited warranty.

The AC-powered, hardwired Kidde i12080 ionization smoke alarm is designed to protect you and your family from the dangers of smoke and fire. This smoke alarm's trademarked hush feature allows you to silence nuisance alarms, while an indicator LED and test feature let you easily confirm that the alarm is working. This wire-in smoke detector also has a battery-backup feature (with included 9-volt battery) as well as a safety light that helps illuminate your path to safety. Kidde i12080 The Kidde i12080 is equipped with an integrated safety light. At a Glance i12080 Hardwire Smoke Alarm At a Glance: Ionization sensing technology detects invisible fire particles Battery backup for continuous protection in case of power outage (battery included) Safety light illuminates your path to safety Smart hush feature silences nuisance alarms Pre-stripped wiring harness with tinned strands 10-year limited warranty At a Glance Features The Kidde i12080 smoke alarm includes a safety light feature that provides 15 minutes of light when the alarm is sounding. It offers a tamper-resistant feature to deter vandalism or theft and a smart interconnect system that connects with up to 24 Kidde devices--including other smoke alarms plus carbon monoxide and heat alarms. The battery-backup feature (9-volt battery included) provides protection even during power outages, when many CO incidences occur. It has a large mounting base that helps protect surface paint from dirt and covers imperfections, and its pre-stripped wiring harness has an easy-off cap and tinned strands to increase conductivity. By pressing the hush button, you can easily and safely silence nuisance alarms caused by non-emergency situations, such as overcooked dinners. This feature desensitizes the alarm for approximately seven minutes. During this time, the alarm chirps every 30 to 40 seconds. If the smoke is too dense, the hush feature is overridden and the alarm still sounds, and the alarm automatically resets at the end of the seven minutes. This convenient safety measure eliminates the temptation to remove the alarm's battery, which creates an unsafe situation. The Kidde i12080 smoke alarm uses ionization sensing technology, which generally detects invisible fire particles (associated with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible particles (associated with smoldering fires) sooner than ionization alarms. Kidde recommends that both ionization and photoelectric smoke alarms be installed to insure maximum detection. What's in the Box One Kidde i12080 120V AC wire-in smoke alarm, one 9-volt battery, and operating and installation instructions. Kidde i12080

  • Ideal for hallways with emergency safety light to guide you to safety. Safety Light illuminates the path to safety
  • Alarm memory flashes red LED indicating which unit was the initiating alarm in interconnected system
  • Interconnectable with up to 24 devices (of which 18 can be initiating) including smoke, CO and heat alarms. See user’s guide for complete instructions
  • Fewer callbacks - One button design for easy operation and less confusion. Operates Hush and alarm test. Battery run down protection will shut down alarm memory when AC power is not present, reducing low battery chirp. Dust cover protects sensor from contaminates during construction reducing nuisance alarms
  • Easy installation - Front battery pull tab allows battery activation without removing alarm from mounting bracket. Large mounting base makes mounting easier, protects surface paint from dirt and covers imperfections. Pre-stripped wiring harness with easy off cap does not require stripper tool. Tinned strands increase conductivity and wire nut grip

User questions & answers

Question: Does i12080 have a dc only version that matched this ac&dc model? (like the rf-sm-dc model
Answer: Pretty sure they are universal but, I can not say with certainty. It comes with it's own base which is very simple to install if the existing base is not compatible.
Question: Will this replace 120-1182B
Answer: Hello. This alarm should have a solid green light when it is getting AC power. It should have a red LED light that flickers every 30 seconds to a minute when in normal standby mode.
Question: Will this replace 120-538b
Answer: yes there are 3 wires in the Kidde i12040 red - hot black - ground white - neutral
Question: Does i12080 replace
Answer: Awwwww, well, I'm not and expert however, I did replace 2 of my detectors with this unit and I did have to change out the plugs.....BUT it was so simple, and they give you everything you need to do so. Took me maybe 10 to 15 minutes and I'm a girl, haha. If you need more tech help, you can Google Kidde who manufactures these and are very helpful with questions. Hope this helps.

Product features

FireX Hardwired 120 Volt Inter-Connectable Ionization Smoke Alarm

Kidde Hardwired Inter connectable Ionization Smoke Alarm with Safety Light features a red LED light that illuminates in an emergency, helping you find the way to safety. The alarm's ionization sensing system detects smoke and fire. A pre-stripped wiring harness makes it easy to connect the alarm to a 120-Volt power source, and an easy-off cap makes replacing the 9-Volt backup battery a breeze.

Kidde i12040 120V AC Wire-In Smoke Alarm with Battery Backup and Smart Hush by Kidde

Home & Tools

Based on 15 reviews Check latest price
  • Hush feature temporarily silences nuisance alarms
  • One touch test button tests unit's electronic circuitry
  • Battery backup 9V battery included
  • Tamper resist locking pin helps deter alarm tampering and theft
  • Kidde smoke alarms meet the UL requirements

User questions & answers

Question: Is the Kidde i12040 the same as the i12040A
Answer: The light should be solid green if it has good batteries and 120 volts to it. You may have a faulty alarm, I would replace it

Kidde 21007624 AC Photoelectric Smoke and Carbon Monoxide Detector Alarm | Hardwired with Battery Backup | Model # KN-COPE-IC

Kidde

Based on 970 reviews Check latest price

Product description

The Kidde Front-Loading Smoke and Carbon Monoxide alarm (part # 21007624) offers protection from two hazards – fire and CO – in one unit. Sold under the FireX brand, this AC-wire with battery backup alarm emits a beeping tone followed by a voice warning that clearly announces the danger by saying, “Fire! Fire!” or “Warning! Carbon Monoxide!”. The uniquely designed frontloading battery compartment makes battery replacement quick and easy, and ensures proper installation. Manufactured with photoelectric sensors for detecting smoke and fire, this alarm also includes the world’s most accurate CO sensing technology based on claims by major manufacturers. Architectural and Engineering Specifications - The combination smoke and carbon monoxide alarm shall be Kidde Unit Number KN-COPE-I (part number 900-0213) or approved equal. It shall be powered by 120VAC, 60Hz source with a 9V battery backup. The temperature operating range shall be between 40°F and 100°F (4°C and 38°C) and the humidity operating range shall be 5% - 95% relative humidity. The unit shall incorporate a photoelectric smoke sensor with nominal sensitivity of 2.05%/ft. The CO sensor shall be of a fuel cell design and shall meet the sensitivity requirements of Underwriters Laboratories UL2034 Single and Multiple Station Carbon Monoxide Detectors. The unit shall qualify for UL-approved wording on the package: “World’s Most Accurate Carbon Monoxide Alarm”. The combination alarm can be installed on the surface of any wall or ceiling following the UL/NFPA/Manufacturer’s recommended placement guidelines. The alarm can be installed on any standard single gang electrical box, up to a 4”octagon junction box. The electrical connection (to the alarm) shall be made with a plug-in connector. The unit shall provide optional tamper resistance that deters removal of the unit from the wall or ceiling. No additional pieces shall be required to activate this feature. A maximum of 24 Kidde devices can be interconnected in a multiple station arrangement. The interconnect system must not exceed the NFPA (National Fire Protection Association) limit of 18 initiating devices, of which 12 can be smoke alarms. With 18 initiating devices (smoke, heat, CO, etc), interconnected, it is still possible to interconnect 6 strobe lights and or relay modules. The alarm shall include a test button that will electronically simulate the presence of smoke and CO and cause the unit to go into both modes of alarm. This sequence tests the unit’s electronics to ensure proper operation. The CO sensor will not alarm to levels of CO below 30 ppm and will alarm in the following time range when exposed to the corresponding levels of CO. 70 ppm CO Concentration 60 – 240 minutes 150 ppm CO Concentration 10 – 50 minutes 400 ppm CO Concentration 4 – 15 minutes The combination alarm shall have two methods of warning for danger: a piezoelectric horn that is rated at 85 decibels at 10 feet and a voice warning that identifies the danger. For a CO incident, the horn will sound in the repetitive manner – four fast beeps, a short pause, four fast beeps, a short pause. In between, the unit will announce “Warning Carbon Monoxide!” In a Smoke incident, the horn will sound in the repetitive manner – three beeps, a pause, three beeps, and a pause. In between, the unit will announce “Fire! Fire!” The unit shall incorporate 2 LED’s. A green LED will be steady on when AC power is present, flash every 30 seconds when in the battery only mode, every 16 seconds to indicate alarm memory, and every 2 seconds to indicate the Hush“mode is active. A red LED will flash in unison with the sounder pattern. The unit shall include the Smart Hush feature that silences the unit for approximately 8 minutes if a nuisance alarm condition occurs. The Green LED on the alarm will flash every 2 seconds while in Smart Hush and will automatically reset itself. It also provides voice annunciation of “Hush Activated” when Smart Hush is activated and “Hush Cancelled” when the Hush cycle ends. The unit shall also indicate a low battery warning utilizing each of the following methods: a brief alarm chirp, the voice announcement of “Low Battery!” The unit shall at a minimum meet the requirements of UL 2034, UL217, NFPA72, (chapter 11 2002 edition) The State of California Fire Marshall, NFPA101 (One and two family dwellings) Federal Housing Authority (FHA), Housing and Urban Development (HUD). It shall also include a 10-year manufacturer’s limited warranty. Claim approved by UL, based on manufacturer’s reported testing.

From the Manufacturer

Front-loading smoke and carbon monoxide alarm offers protection from both fire and CO in one unit. AC-wired with battery backup alarm emits beepoing tone followed by a voice warning. The uniquely designed front-loading battery compartment makes battery replacement quick and easy and ensures proper installation. Made with photoelectric sensors for detecting smoke and fire, this alarm also includes the world's most accurate CO sensing technology.

  • Provides protection from fire and carbon monoxide in one unit with Photoelectric sensor.
  • Fire Warning - The red LED will flash and be accompanied by three long alarm beeps followed by a verbal warning message “FIRE! FIRE!”. The alarm will repeat pattern until unit is reset or smoke is eliminated.
  • Carbon Monoxide Warning - Four short alarm beeps followed by a verbal warning “WARNING! CARBON MONOXIDE!” This continues until the unit is reset or the CO is eliminated.
  • Low Battery Warning - One chirp followed by warning “LOW BATTERY”. The red LED light will flash. This pattern will continue every minute for the first hour. After the first hour the red LED light will flash once every minute accompanied by the chirp sound. The “LOW BATTERY” warning will only sound once every fifteen minutes. Voice Hush Indication: “HUSH ACTIVATED” and “HUSH CANCELLED” voice announcement
  • Alarm Memory - The green LED will blink once every 16 seconds to alert a user when the unit has alarmed for smoke or has detected a concentration of CO. If the alarm has detected a CO level of 100ppm or greater, when the Test/Reset button is pressed the unit will announce “CO PREVIOUSLY DETECTED”. If the alarm has detected abnormal levels of smoke since its last test, it will produce three rapid beeps.
  • AC-Wire with battery backup, An included 9V battery protects during short-term power outages
  • Front-loading battery with unique battery door design

User questions & answers

Question: Will this co alarm expire in 5-7 years like most other co alarms
Answer: It will last 10 years according to the warranty and user manual. Ten years after initial power-up, this unit will “chirp” twice every 30 seconds to indicate that it is time to replace the alarm. A label has been provided on the side of the alarm that has “Replace by” printed on it. Write the replace by date on the label. The date written on the label should be ten (10) years after the alarm was initially powered. This alarm does have end of life Hush® which allows you to silence the trouble chirp for two days giving you extra time to replace the unit when it is more convenient. To activate, press the test/reset button. While in the End of Life Hush® mode, will still detect CO and Smoke. This feature can only be used for 30 days from the time the unit first indicates end of life. At the end of the 30 day period the alarm cannot be hushed and must be replaced immediately.
Question: I want to replace all my Kidde 1276 detectors. I want one of the new ones to also be CO2 detector. Is this unit compatible with the
Answer: Yes. You can see that in the owner's manual. http://dms.hvacpartners.com//docs/2001/Public/0B/User-Guide-KN-COPE-I-ENG-(2528.pdf
Question: Can i replace a kidde p12040 (hardwired smoke detector) with this model (hardwired combo)? same company and same 3 pins on the back
Answer: I'm fairly sure you can. They even offer adapters that allowed them to replace my old Firex wired-in detectors.
Question: We have these in a 165 room hotel. They are not lasting. I have had to replace 6 and need another 6 today. What recourse do we have
Answer: Welcome to the club, I have been having the same problem only on a much smaller scale. Try contacting Kidde and see what they say, however if you read the installation instructions that come with each unit it states they only last 7 - 10 years before having to be replaced. I believe that is from the date of manufacture (the units are marked) and not the install date. The units I replaced are right at the low end of the replacement dates. Good luck.

Product features

Always Alert

In order to monitor your home even if you are away, this detector includes an Alarm Memory feature. If the green LED is blinking once every 16 seconds, the unit has detected CO levels of 100PPM or higher, or detected smoke and then ceased its alarm. Pressing the Test/Reset will reset the memory and inform you of the hazard detected.

Easy to Install

Ensure the safety of your family and home with the combination smoke and carbon monoxide alarm from Kidde. This is a hardwired alarm that can be used in an interconnected system, and it features a battery backup, in addition to voice alerts. Using an advanced photoelectric sensor, capable of detecting visible fire particles associated with smoldering fires, and an electrochemical sensor for CO detection, you can rest easy and feel protected.

Easy Access

If the low battery warning sounds, there is a convenient front-loading battery door so that you don’t have to remove the alarm from its mounting bracket to replace the alarm. Additionally, to ensure that there is always a properly functioning battery, the battery compartment will not close if the battery is not installed correctly.