14 best mastercool refrigerant leak detectors
Mastercool refrigerant leak detectors are specialized tools used in the automotive and HVAC (heating, ventilation, and air conditioning) industries. These detectors are designed to identify and locate refrigerant leaks in air conditioning systems and automotive air conditioning systems. Here are some key points about Mastercool refrigerant leak detectors:
Purpose: The primary purpose of these detectors is to identify refrigerant leaks, which can be harmful to the environment and reduce the efficiency of cooling systems. Detecting and repairing these leaks is crucial for environmental compliance and system performance.
Refrigerant Types: Mastercool leak detectors are designed to detect various types of refrigerants, including commonly used ones like R-134a, R-410a, and R-22. The ability to detect multiple refrigerant types is important for technicians who work with different systems.
Sensitivity: These detectors are known for their sensitivity in detecting even small refrigerant leaks. They use advanced sensor technology to pick up trace amounts of refrigerant gas in the surrounding air.
Visual and Audible Alerts: When a leak is detected, Mastercool refrigerant leak detectors typically provide both visual and audible alerts to the technician. This makes it easier to pinpoint the location of the leak.
Adjustable Sensitivity: Many models allow technicians to adjust the sensitivity level, helping them differentiate between small and large leaks and ensuring accurate detection.
Probe and Sensor: The detectors come with a probe or sensor that is used to scan the area around potential leak points, such as joints, fittings, and connections in air conditioning systems. Some models may have flexible probes for reaching tight spaces.
Battery-Powered: Most Mastercool leak detectors are battery-powered for portability and ease of use. Battery life can vary depending on the model and usage.
Certifications: These detectors may meet industry standards and certifications, ensuring their reliability and accuracy. Compliance with industry regulations is essential for technicians and automotive professionals.
Ease of Use: Mastercool detectors are typically designed to be user-friendly, with straightforward controls and clear displays. This allows technicians to quickly and efficiently locate leaks.
Application: These detectors are widely used by automotive technicians, HVAC professionals, and refrigeration specialists for routine maintenance, diagnostics, and repairs of cooling systems.
Maintenance: Regular maintenance and calibration may be required to ensure the continued accuracy and reliability of the detectors.
In summary, Mastercool refrigerant leak detectors are essential tools for technicians and professionals in the automotive and HVAC industries. They are designed to detect refrigerant leaks with high sensitivity, provide visual and audible alerts, and help locate leaks in air conditioning systems. These detectors play a crucial role in environmental compliance and the efficient operation of cooling systems.
Below you can find our editor's choice of the best mastercool refrigerant leak detectors on the marketProduct description
The “Raptor” refrigerant leak detector by Mastercool offers an accurate and reliable solution to electronic leak detection. This unit offers state-of-the-art features and micro-processing technology while the design sensor delivers a precise and instant response. This unit is packaged in a custom molded case with 2 “C” batteries and sensor tip.
- DIGITAL SIGNAL MICRO-PROCESSOR provides precise and instant responses
- SENSITIVITY LEVEL ADJUSTMENT with 3 levels of sensitivity and 5 levels of detection
- STATE OF THE ART FEATURES including visual leak level indicator, keypad control and reset function
- VARIABLE FREQUENCY audible alarm
- DETECTS ALL REFRIGERANTS CFC’s , HCFC’s, HFC’s and blends
- Fit type: Universal Fit
User questions & answers
Question: | What type detector is this? heated diode/ir/electrolyte/corona |
Answer: | we had two versions of the items, one is with US outlets and one is with EU outlets, but recently we have removed the EU outlet inventory. if you need a US outlet, please email us at [email protected]. |
Question: | will this detector locate 410a leaks |
Answer: | Yes, it can detect HFO such as R1234YF. |
Product features
Raptor Refrigerant Leak Detector
The "Raptor" refrigerant leak detector offers state-of-the-art features and micro-processing technology while the design sensor delivers an accurate and instantaneous response. Provides electronic leak detection of even the toughest leaks.
Packaged in a blow molded case with UV glasses, 2 “C” batteries and sensor tip.
State-Of-The-Art Features
The sensor of the "Raptor" refrigerant leak detector can detect all refrigerants (CFC's, HCFC's, HFC's and blends) with a life that is approximately 20 hours. The 3 levels of sensitivity with 5 levels of detection can find leaks as small as 1/10 oz per year.
Reset Function
The primary use for the RESET function is to pinpoint the leak source. When the unit detects a leak and goes into full alarm, press the RESET button. Resetting will ignore any leaks at that level and only detect leaks of higher concentration.
Turn OFF System Before Inspection
Make sure that the air conditioning/refrigeration system is turned OFF before inspection. A sufficient amount of refrigerant must be present in the system. A minimum gauge pressure of 50 PSI at ambient temperature of 60˚ and above with the system OFF is required for efficient leak detection.
Working With The Flexible Probe
For the best leak detection results, the probe should be moved across the leak detection area at the rate of 1” - 2” per second (25 - 50mm per second) and held 1/4” (5mm) away from the surface. An increase in the alarm rate will indicate a leak. To confirm the correct leak location, blow shop air around the suspected leak area, move the probe into fresh air, reset and reinspect.
High Humidity and Erratic Alarm
When inspecting in contaminated or high humidity areas, erratic alarming may occur. For best results in these areas, allow the unit to adjust to the existing environment before inspecting. Pressing the RESET button will adjust the unit to an existing environment.
Product description
The Mastercool Professional UV Leak Detector Kit with 50W Mini Light includes high intensity mini light, replaceable 1 oz. (10 applications) dye cartridge, A/C connection hose w/R134a coupler, R12 adapter, 1 oz. OIL/ATF/Gas and diesel fluorescent dye, 1 oz. engine coolant dye, 4 oz. dye remover, 25 service information labels and UV enhancing safety glasses.
- High intensity mini 12V/50W UV light
- A/C connection hose with R134a coupler
- Replaceable 1 oz. (10 applications) dye cartridge
- Oil/ATF/Gas and diesel fluorescent dye (1 oz. ), engine coolant dye (1 oz. )
User questions & answers
Question: | Do i have to buy refrigerant separately |
Answer: | Since I used the fluorescent dye to detect leaks from the power-steering system I had to drive my car around for approx 15 mins to actually see where it was leaking from. At idle I couldn't see any leaks. After the drive the leak was pretty obvious and the UV light picked it up right away. |
Question: | does it come with dye for a/c |
Answer: | Negative corona |
Question: | are glasses included |
Answer: | THIS UNIT WORKS WITH (CFC'S, HCFC'S, AND HFC'S) 410A IS A HFC. |
Question: | How long should i keep the engine running for UV dye to show up? And do i have to rev it or just idle it |
Answer: | Yes, i have yet to see a refridgerant leak detector that was 100% accurate. In my opinion the Inficon Tekmate us more accurate than the Elitech. The Elitech works well but not great. |
Product description
Detects all Refrigerants as low as 1/10 oz. per year Eliminates many false responses Heated Tin Oxide Element High, Medium and Low sensitivity The 55900 meets and exceeds all certification required by SAE for all refrigerants including the new R1234yf The intelligent microprocessor and sensor design eliminates many false responses from common automotive materials High, Medium and Low sensitivity with a 2000-hour sensor life Detects all refrigerants as low as 1/10 oz. per year Six multi-colored LED lights display with alarm Peak feature to assist with detection of multiple leaks
- "Super Sensitive Function" allows the unit further sensitizing beyond the standard settings for locating small leaks with gases such as R1234yf and R407C
- Intelligent tip design that senses the condition of the environment, to eliminate the potential of false alarms
- Detects all refrigerants (CFC's, HCFC's, & HFC's and blends)
- Flexible 15. 5" probe for difficult to reach locations
- Sensing Element: Heated tin oxide
- Fit Type: Universal
Product features
THE ONLY COMPACT LEAK DETECTOR YOU WILL EVER NEED...
At the heart of this leak detector is a new low power metal oxide gas sensor with superior performance properties. The sensor is characterized by high sensitivity and fast response upon detecting the presence of extremely small levels of chlorofluorocarbon gases.
A powerful microprocessor was integrated into the design that automatically selects the best operating condition for the sensor to ensure optimum performance throughout its life.
PROBE
- Intelligent tip, with environment sensing element to eliminate the potential of false alarms
- Flexible 15.5 inch probe length for difficult to reach locations
LED DISPLAY
Six vertical LED display with enabled selectively (red, yellow or green) to display information to the user such as:
- The relative signal level of the detected leak
- The selected sensitivity range (low/medium or high) of the unit
- Diagnostic information: low battery, interference/wait, contaminated atmosphere readiness of the unit or fault conditions of the unit
KEYPAD CONTROLS
- ON/OFF button (push-on/push-off)
- Volume/Mute button (high, low or mute)
- Sensitivity button for High, Medium and Low sensitivity level selection
- Peak button The PEAK/HR/LR key serves a dual purpose: To assist the user in locating the “largest leak” in a system with multiple leaks present. To enable the user to switch between HR (high range) and LR (low range) modes.
Product description
The “Raptor” refrigerant leak detector by Mastercool offers an accurate and reliable solution to electronic and UV leak detection. This unit offers state-of-the-art features and micro-processing technology while the design sensor delivers a precise and instant response. The ultra-bright UV light built into the end of the probe allows for both electronic and UV leak detection of even the hardest to find leaks. This unit is packaged in a custom molded case with UV glasses, 2 “C” batteries and sensor tip.
- DIGITAL SIGNAL MICRO-PROCESSOR provides precise and instant responses
- SENSITIVITY LEVEL ADJUSTMENT with 6 levels of sensitivity and 15 levels of detection
- STATE OF THE ART FEATURES including visual leak level indicator, keypad control, mute and reset function
- VARIABLE FREQUENCY audible alarm
- UV/BLUE LED LIGHT is built into the end of the unit to provide ultra bright UV leak detection
- Fit type: Universal Fit
User questions & answers
Question: | Does the work with 1234yf |
Answer: | Yes. They are an amber/yellow color |
Product features
Raptor" Refrigerant Leak Detector with Ultra Violet Blue Light
The "Raptor" refrigerant leak detector with UV blue light offers state-of-the-art features and micro-processing technology while the design sensor delivers an accurate and instantaneous response. An ultra bright UV light is built into the end of the probe allowing for both electronic and UV leak detection of even the toughest leaks.
Packaged in a blow molded case with UV glasses, 2 “C” batteries and sensor tip.
State-Of-The-Art Features
The sensor of the "Raptor" refrigerant leak detector can detect all refrigerants (CFC's, HCFC's, HFC's and blends) with a life of approximately 20 hours. The six levels of sensitivity with 15 levels of detection can find leaks as small as 1/10 oz per year.
Ultra Bright UV Light
Ultra bright UV light is built into the end of the probe allowing for both electronic and UV leak detection of even the toughest leaks.
Turn OFF System Before Inspection
Make sure that the air conditioning/refrigeration system is turned OFF before inspection. A sufficient amount of refrigerant must be present in the system. A minimum gauge pressure of 50 PSI at ambient temperature of 60˚ and above with the system OFF is required for efficient leak detection.
Working With The Flexible Probe
For the best leak detection results, the probe should be moved across the leak detection area at the rate of 1” - 2” per second (25 - 50mm per second) and held 1/4” (5mm) away from the surface. An increase in the alarm rate will indicate a leak. To confirm the correct leak location, blow shop air around the suspected leak area, move the probe into fresh air, reset and reinspect.
High Humidity and Erratic Alarm
When inspecting in contaminated or high humidity areas, erratic alarming may occur. For best results in these areas, allow the unit to adjust to the existing environment before inspecting. Pressing the RESET button will adjust the unit to an existing environment.
Product description
Mastercool 55850 Intellasense Refrigerant Leak Detector KitThe 55800 leak detector employs a new metal oxide gas sensor for the detection of chlorofluorocarbon gasses and blends. This tin oxide sensor is characterized by high sensitivity and a fast response, upon detecting the presence of extremely small levels of chlorofluorocarbon gases. Integrated into the design is a powerful microprocessor that automatically selects the best operating conditions for the sensor, to ensure optimum performance. The optimum sensor performance is maintained and monitored throughout the life of the sensor.'Super Sensitive Function' allows the unit further sensitizing beyond the standard settings for locating small leaks with gases such as R1234yf and R407CLCD FEATURES: WAIT: This indication flashes whenever the unit is in the wait mode. This could occur whenever the unit is turned on or interference is detected READY: This indication appears when the unit is ready for use INT: This indication appears whenever the microprocessor detects conditions that are not suitable for reliable leak detection. Excessive wind blowing, blocked probe (no air flow), burned out fan, or a missing or defective sensor that needs to be replaced BATTERY SYMBOL: When the battery symbol becomes illuminated this is an indication that the battery is low and needs to be replaced H - M - L: High, Medium and Low sensitivity ranges will be displayed accordingly based on the selection made on the keypad SIGNAL LEVEL BARS: There are 10 vertical signal level bars on the display corresponding to the level of signal detected by the unit ERROR SIGNALS: E1 through E9 indicates diagnostic signalsKEYPAD FUNCTIONS: ON/OFF: Press the ON/OFF button on the center of the keypad to turn the unit on or off VOLUME/MUTE: Press the VOLUME/MUTE button to control the volume of the unit H M L SENSITIVITY: Press the H M L SENSITIVITY button to select the desired sensitivity level HOLD: Pres
- IntellaSense Refrigerant Leak Detector Kit
- Detects:
- Hydrogen
- Refrigerants: All CFC's, HCFC's & HFC's
Product description
Leading the way in UV leak detection, Mastercool offers a variety of compact UV leak locator kits. Each kit offers a powerful inspection lamp, a “refillable” or “cartridge type” dye injector and accessories. All kits are packaged in a clam shell or custom molded carrying case.
- RECHARGEABLE TRUE UV LIGHT KIT includes AAA and rechargeable batteries, battery holder, 110V charger, refillable 2 oz dye injector, 2 oz concentrated universal A/C fluorescent dye (25 applications), 4 oz dye remover, 25 service information labels, and UV safety glasses
- UV WAVELENGTH of 390-400
- 154 – 170 µW/cm2 which is compatible to a 50 watt UV flashlight
- 154 – 170 µW/cm2 which is compatible to a 50 watt UV flashlight
- ALUMINUM BODY WITH ANODIZED FINISH makes this flashlight extremely durable
- ALL OF THE TOOLS NECESSARY for complete UV leak detection
User questions & answers
Question: | Can this be used for residential refrigerators |
Answer: | Yes. It does come with a storage case. What’s you see that’s what you get |
Question: | will this work with r |
Answer: | The 55900 is certified for all refrigerants including 1234YF. |
Question: | Will this work on a 410a system |
Answer: | Comes with c-cell batteries. glasses and extra sensor tip. No dye. |
Question: | Is it come with storage case |
Answer: | Yes, it has a plastic case. |
Product features
RECHARGEABLE UV LEAK LOCATOR KIT
Mastercool's rechargeable UV leak locator kit includes: a rechargeable UV light, AAA and rechargeable batteries, battery holder, 110V charger, refillable 2 oz dye injector, 2 oz concentrated universal A/C fluorescent dye (25 applications), 4 oz dye remover, 25 service information labels, and UV safety glasses.
The UV flashlight is compact and easily rechargeable using the included 110V charger. Never be without power with the AAA battery holder providing backup power to the flashlight.
Rechargeable, Durable UV Flashlight
The aluminum body with anodized finish makes this flashlight extremely durable while the easy grip texture makes it easy to hold onto in tight places.
Never Be Without Power
Easily recharge with the included 110V battery charger or if you aren't near a convenient charging area, load the flashlight with 3 AAA batteries.
Product description
Certified to Meet J2791 (R134A), J2913 (R1234YF) & EN 14624 Detects all refrigerants Heated tin oxide element, 2,000 hour sensor life 3 sensitivity levels
User questions & answers
Question: | Will this work on other AC refrigerants,134—r |
Answer: | Yes it comes with a/c dye |
Product description
The 55200 "INSPECTOR" offers revolutionary NEW features and state of the art micro processing technology. The NEW design sensor delivers an accurate and instantaneous response.
- Ultra Bright UV/Blue LED Light
- 6 Levels of Sensitivity (15 Levels of Detection)
- Tri-Colored Visual Leak Level Indicator
- Meets SAE J1627 and CE Conformity
- Detects all refrigerants (CFC's, HCFC's, HFC's)
User questions & answers
Question: | Can this work with 1234 refrigerant |
Answer: | work only on 1234YF and 134A. will not work on R12 |
Question: | what type of batteries,come with glasses, dye, extra tips, heated tip |
Answer: | THE 56200 WAS DESIGNED TO WORK WITH 134a REFRIGERANT. WE ALSO HAVE MASTERCOOL PART# 55900 DESIGNED TO WORK WITH 1234YF AND 134A REFRIGERANTS. |
Question: | Does this Item have a platic case with it |
Answer: | Yes, it’s not supplied with kit |
Product description
55850, Intellasense Refrigerant Leak Detector Kit
55850 Includes only:
- 55800 IntellaSense refrigerant leak detector
- 53512 12 LED UV light
- 92398 UV safety glasses
- 2 "D" batteries
- Leak test vial
- Blow molded case
- Replacement filters
Detects:
- Combustible Gases
- Hydrogen
- Refrigerants: All CFC's, HCFC's and HFC's
The 55800 leak detector employs a new metal oxide gas sensor for the detection of chlorofluorocarbon gasses and blends. This tin oxide sensor is characterized by high sensitivity and a fast response, upon detecting the presence of extremely small levels of chlorofluorocarbon gases. Integrated into the design is a powerfulmicroprocessor that automatically selects the best operating conditions for the sensor, to ensure optimum performance. The optimum sensor performance is maintained and monitored throughout the life of the sensor.
Product description
Mastercool, 55800, IntellaSense Refrigerant Electronic Leak Detector With LCD 55800 Includes only: Blow molded case 2 "D" batteries Leak test vial Replacement filters Detects: Combustible Gases Hydrogen Refrigerants: All CFC's, HCFC's and HFC's The leak detector employs a new metal oxide gas sensor for the detection of chlorofluorocarbon gasses and blends. This tin oxide sensor is characterized by high sensitivity and a fast response, upon detecting the presence of extremely small levels of chlorofluorocarbon gases. Integrated into the design is a powerful microprocessor that automatically selects the best operating conditions for the sensor, to ensure optimum performance. The optimum sensor performance is maintained and monitored throughout the life of the sensor. LCD Features with all optional accessories: WAIT: This indication flashes whenever the unit is in the wait mode. This could occur whenever the unit is turned on or interference is detected READY: This indication appears when the unit is ready for use INT: This indication appears whenever the microprocessor detects conditions that are not suitable for reliable leak detection. Excessive wind blowing, blocked probe (no air flow), burned out fan, or a missing or defective sensor that needs to be replaced BATTERY SYMBOL: When the battery symbol becomes illuminated this is an indication that the battery is low and needs to be replaced H - M - L: High, Medium and Low sensitivity ranges will be displayed accordingly based on the selection made on the keypad SIGNAL LEVEL BARS: There are 10 vertical signal level bars on the display corresponding to the level of signal detected by the unit ERROR SIGNALS: E1 through E9 indicates diagnostic signals Keypad Functions: ON/OFF: Press the ON/OFF button on the center of the keypad to turn the unit on or off VOLUME/MUTE: Press the VOLUME/MUTE button to control the volume of the unit H M L SENSITIVITY: Press the H M L SENSITIVITY button to select the desired sensitivity
Product description
Digital signal micro processor Visual leak level indicator Reset function Keypad control Sensitivity level adjustment Battery test function Variable frequency audible alarm 3 Levels of Sensitivity (5 Levels of Detection) Detects leaks as small as 1/10 oz per year Detects all refrigerants (CFC’s, HCFC’s, HFC’s) Meets and exceeds SAE J1627 Power: 2 “C” Batteries Probe: Flexible 16” (43 cm) Packaged in a blow molded case
Product description
This kit fabricates: Push Connect 1/4, 5/16 and 3/8”, GM Fuel Line Flare, Brake Lines and Transmission 5/16 and 3/8”, Flare/Double Flare 3/16, 1/4, 5/16, 3/8 and 1/2”, Metric Bubble Flare 4. 75, 6, 8, and 10 mm, GM Transmission Cooling Lines (jiffy-tight) 3/8 and 1/2”. Comes in a custom molded box with a mini tube cutter. PATENT# 5, 782, 128
- TUBE AND DIE SET STABILIZING ARM for easy tube forming
- MAGNETIC ADAPTER HOLDER keeps adapters in place
- EQUIPPED WITH AN ENLARGED DIE SET COMPRESSION AREA for better grip of dies
- CAN BE USED ON "annealed steel" & "dead soft"
- INCLUDES dies and adapters to fabricate push connect 1/4, 5/16 and 3/8"; GM fuel line flare, brake lines and transmission 5/16 and 3/8"; flare/double flare 3/16, 1/4, 5/16, 3/8 and 1/2"; metric bubble flare 4. 75, 6, 8, and 10mm; GM transmission cooling line 3/8" and 1/2"; mini tube cutter for 1/8" to 5/8" (3 - 16 mm) O. D. tubing (1/8 to 1/2" nominal) all packaged in a custom blow molded case
User questions & answers
Question: | are repair parts available |
Answer: | THERE IS A REPAIR KIT FOR THE HYDRAULIC PUMP. |
Question: | prc: is this the most inclusive mastercool kit? i want a line kit that will pretty much do everything. is this their best kit to order? thanks |
Answer: | Yes, this is the most complete kit on the market. This kit will allow you to create flares on fuel, brake and transmission lines including jify-tite 1/2” and 3/8”. |
Question: | Free returns? states "free returns" when viewing item on my android |
Answer: | Yes |
Question: | Whats the warranty |
Answer: | THE HYDRAULIC PUMP COMES WITH A FULL 1 YEAR WARRANTY. THE ADAPTERS AND DIES COME WITH A 90 DAY WARRANTY. |
Product features
Fabricate Flares with Ease
This kit fabricates: Push Connect 1/4, 5/16 and 3/8”, GM Fuel Line Flare, Brake Lines and Transmission 5/16 and 3/8”, 45˚ Flare/Double Flare 3/16, 1/4, 5/16, 3/8 and 1/2”, Metric Bubble Flare 4.75, 6, 8, and 10 mm, GM Transmission Cooling Line 3/8 and 1/2”. Also included in the plastic box is Mastercool's Mini Tube Cutter for 1/8" to 5/8" (3-16 mm) O.D. tubing (Patent # 6324884)
Set Includes:
Push Connect
Fabricate 1/4, 5/16" and 3/8" push connect flares.
GM Fuel Line, Brake Lines and Transmission
Fabricate 5/16 and 3/8" GM fuel line, brake lines and transmission flares.
45˚ and Double Flare / ISO Bubble Flare
Fabricate 3/16", 1/4", 5/16", 3/8" and 1/2" 45˚ and double flares
Fabricate 4.75 mm, 6 mm, 8 mm, 10 mm metric bubble flares.
GM Transmission Cooling Line
Fabricate 3/8" and 1/2" GM transmission cooling line flares.
Product description
The ACCU-CHARGE II is the most advanced scale on the market today! Constructed of rugged die cast aluminum, the heavy duty 9" x 9" platform can be easily removed from the ABS case and carried to any convenient location.
- RUGGED AND COMPACT DESIGN allows for easy portability to any job site
- NON-SLIP 9 x 9” PLATFORM for easy weighing of refrigerant tanks with an accuracy of ≤±0.05% of reading
- EXTRA LARGE LCD DISPLAY for easy reading from any angle
- HIGH CAPACITY up to 243 lbs
- CHARGE PROGRAMMING allows the user to program desired quantities. Before the charge is complete, an alarm will sound allowing ample time to turn off the refrigerant supply
User questions & answers
Question: | Does the scale have a calibration function or procedure |
Answer: | As far as I know there is a zeroing function but I guess you would have to use a known weight and use that as your zero point. |
Question: | What kind of batteries does this scale use |
Answer: | AA BATTERIES. |
Question: | What type of warranty does this product have |
Answer: | 30 days from us and 1 year from manufacture. |
Question: | HOW MUCH FREON CAN IT WEIGH |
Answer: | From the Specifications it says: Capacity: 243 lbs (110 kgs)* Accuracy:±6 gr (0.16 oz) / ±0.01 lb / ±0.01 Kgor 0.1% of reading whichever is greater* Resolution: 0.05 lb/0.4 oz (0.01 kg) |
Product features
Accu-Charge II Electronic Scale
Mastercool's Accu-Charge II Electronic Scale features charge programming which allows the user to program desired quantities. Before the charge is complete, an alarm will sound allowing ample time to turn off the refrigerant supply. Tank capacity programming allows the user to know the amount of refrigerant in the tank at any given time. The repeat function allows for charging a previously stored amount.
This unit is the ultimate device for the charging and recovering of refrigerants.
The Ultimate Device for Charging and Recovering of Refrigerant
Strong aluminum base with a rugged, non-slip platform provides extra durability while working in any environment.
The included compact and heavy-duty carrying case allows for easy portability to any job site.
Manufactured for Performance
The large 9 x 9" platform provides for easy weighing of refrigerant tanks with an accuracy of ≤±0.05% of reading.
This scale also features an extra-large LCD display for easy reading from any angle and features three display modes (kgs, lbs, oz). With a high capacity of up to 243 lbs (110 kgs) it is easily one of the best on the market.
Easy to Use Keypad
- ON/OFF: Turn unit ON or OFF
- UNIT - Select readout in lb, oz or kg
- SHIFT - Move from one digit to the next, to edit display, to set up tank capacity
- CHARGE - To start CHARGE/RECOVERY mode
- PAUSE - To pause & resume in CHARGE/RECOVERY mode
- TARE - Zeros out display in BASIC CHARGING
- ENTER - To start operation or input data
- REPEAT: To repeat the last action
- CLEAR: To clear the display during PROGRAM CHARGING
Product description
Remove the complications that often result from unreliable rubber plugs or bladders with our heavy duty cooling system pressure test & refill kit. This kit will save set-up time and provide precise test results. Uses shop air to uphold continual pressure to the cooling system during testing and refill4 quick disconnect vacuum attachments provide quick refilling of the cooling system and eradicates airlocks For use with Freightliner, International, Kenworth, Peterbilt, Mack, Volvo, GMC and Sterling cooling systems Includes heavy duty vehicle adapters, pressure test regulator, vacuum refill attachment with tubing in a plastic case
- this kit will save set-up time and provide precise test results.
- uses shop air to uphold continual pressure to the cooling system during testing and refill
- 4 quick disconnect vacuum attachments provide quick refilling of the cooling system and eradicates airlocks
- for use with freightliner, international, Kenworth, Peterbilt, mack, Volvo, GMC and Sterling cooling systems
- Includes heavy duty vehicle adapters, pressure test regulator, vacuum refill attachment with tubing in a plastic case
- Fit type: Universal Fit
User questions & answers
Question: | Does it fit semi trucks as volvo, freightliner , mack, peterbilt etc |
Answer: | Not Volvo HD. |
Latest Reviews
View all
Kf Baby Cribs
- Updated: 18.07.2023
- Read reviews

Luggage Set Spinner Wheel
- Updated: 22.02.2023
- Read reviews

Knee Brace With Pads
- Updated: 20.07.2023
- Read reviews

Dj Equipment
- Updated: 26.04.2023
- Read reviews

Rubber Bin
- Updated: 07.04.2023
- Read reviews